Emergency Stop Relays, Safety Gate Monitors
Category 4, EN 954-1
PNOZ X3
Emergency stop relay and safety
gate monitor in accordance with
VDE 0113, 11/98, EN 60204-1, 12/97
and IEC 204-1, 11/98, safety
component in accordance with the
Lift Directive 95/16/EC and EN 81-1/
1998
Features
Monitored manual or automatic
reset can be selected
1 semiconductor output (K1/K2)
Each AC unit can be operated
with 24 VDC
Safety gate function with
N/C-N/O combination
Only dual-channel operation will
detect shorts across the input
contacts
Technical Details PNOZ X3
Electrical Data
Supply Voltage AC: 24, 42, 48, 110, 115, 120, 230, 240 V
DC: 24 V
Tolerance 85 ... 110 %
Power Consumption Approx.2.5 W/5 VA
Voltage and Current at the Input and 24 VDC, 35 mA
Reset Circuits and Feedback Control Loop
Switching Capability in accordance with
EN 60947-4-1, 10/91 AC1: 240 V/8 A/2000 VA
DC1: 24 V/8 A/200 W
EN 60947-5-1, 10/91 AC15: 230 V/5 A; DC13: 24 V/6A
(DC13: 6 cycles/min.)
Output Contacts 3 safety contacts (N/O),
1 auxiliary contact (N/C)
Contact Fuse Protection 10 A quick or 6 A slow
(EN 60947-5-1, 10/91)
Semiconductor Outputs 24 VDC/20 mA, short-circuit protected
External Supply Voltage 24 VDC ±20 %
Times
Delay-on Energisation Monitored manual reset: max. 100 ms
Auto./ manual reset: max. 0.3 s
Delay-on De-energisation With E-STOP: max. 80 ms
With power failure: max. 1 s
Recovery Time Approx. 1 s
Simultaneity channel 1/2
Max. Supply Interruption before De-energisation Approx. 25 ms
Environmental Data
Ambient Temperature -25 ... +55 °C
Mechanical Data
Maximum Cross Section of 2 x 1.5 mm2 or 1 x 2.5 mm2
External Conductors Single-core or multi-core
with crimp connectors
Dimensions (H x W x D) 87 x 45 x 121 mm
Weight 420 g
Description
45 mm, P-93 housing, DIN-Rail
mounting
Positive-guided relay outputs:
– 3 safety contacts (N/O)
– 1 auxiliary contact (N/C)
Connections for
– E-STOP button
– safety gate limit switch
– reset button
Semiconductor output signals
ready for operation
LEDs for channel 1, channel 2 and
power
Increase in the number of
safety contacts available by
connecting expander modules.
Operating Modes
Single-channel operation
Dual-channel operation
Automatic reset
Monitored manual reset
General Technical Data
Unless stated otherwise in the technical details for the specific unit
Electrical Data
Frequency Range AC 50 ... 60 Hz
Residual Ripple DC 160 %
Contact Material AgSnO2
Continuous Duty 100 %
Environmental Data
EMC EN 50081-1, 01/92, EN 50082-2, 03/95
Vibration in accordance with Frequency: 10 ... 55 Hz,
EN 60068-2-6, 04/95 Amplitude: 0.35 mm
Climatic Suitability DIN IEC 60068-2-3, 12/86
Airgap Creepage DIN VDE 0110 part 1, 04/97
Ambient Temperature -10 ... +55 °C
Storage Temperature -40 ... +85 °C
Mechanical Data
Torque Setting on Connection Terminals 0.6 Nm (screws)
Mounting Position Any
Housing Material Thermoplast Noryl SE 100
Protection Mounting: IP 54
Housing: IP 40
Terminal Range: IP 20
The units were tested in accordance with the relevant standards current at
the time of development.
Order References
Type UB Order No.
PNOZ X3 24 V AC/24 V DC 774 310
PNOZ X3 42 V AC/24 V DC 774 311
PNOZ X3 48 V AC/24 V DC 774 312
PNOZ X3 110 V AC/24 V DC 774 314
PNOZ X3 115 V AC/24 V DC 774 315
PNOZ X3 120 V AC/24 V DC 774 316
PNOZ X3 230 V AC/24 V DC 774 318
PNOZ X3 240 V AC/24 V DC 774 319